skip to content »

vdv345polk.ru

Sccm collections system ou not updating

sccm collections system ou not updating-14

Be sure that you have your parent App-V application added to SCCM, first, before you create the Script Installer.

sccm collections system ou not updating-86sccm collections system ou not updating-16

The negative result of these updates is that it essentially breaks a large majority of our current dictation microphones, the Dictaphone Power Mic II. Let’s consider the two following situations: Situation 1 The reason for this breaking is because of the following Microsoft security updates.Microsoft has released updated USB drivers which will cause the older Power Mic II devices to not work.These updates, and information about the patches, can be found in the following security bulletins: The affected drivers from these releases are found in the following locations: USB Audio %systemroot%\inf\wdma_%systemroot%\System32\Driver Store\File Repository\wdma_usb.inf_x86_xxx_xxx USB %systemroot%\inf\%systemroot%\System32\Driver Store\File Repository\input.inf_x86_xxx_xxx There may be additional changes in these patches, but it is a larger issue to decommission half of our devices at once with a single set of updates.In working with the cases that I anticipate to be facing with some of our more high-profile customers, I will be taking careful note for tips and tricks as well as streamlined or custom approaches to resolving and preventing issues. Recently, we have been planning and testing an upgrade of the DMNE client to an updated service pack in preparation for the update to version 12.This is an exciting time for me and I hope that my readers will continue to benefit from the knowledge that I will continue to share here. During the testing phase, however, we found that somewhere along the process, the Power Mic II devices began malfunctioning.It always goes somewhere under the App-V folder using the Package ID and Version ID of the published application.

I decided that a symlink could possibly work for this situation since the app seemed to run fine and only complained about the file location.

I created a new symlink in C:\Program Files\ with the following command from a Power Shell terminal: allowed the application to run without issue.

If this application was going to work as an App-V package, an automated way to perform this symlink creation would need to be implemented so that the user would have a working App-V delivery without any additional wait or hassle.

Be sure to read through the security bulletins to decide what’s best for you. ~Scriptd EEZ In working with sequencing different App-V 5 applications, I’ve found there can be requirements for binaries to exist at absolute paths in C:\Program Files.

This is somewhat problematic because, from what I can find, there is no built-in or easy way to deliver packages to their originally named, and absolute location on a system. We can use some custom scripting to help us out along with the help of System Center Configuration Manager 2012 R2.

We can then configure pointing to “C:\Program Files\” during sequencing the App-V 5 applications, or by editing the Deployment after sequencing.